  • Can use natural gas or propane gas
  • ½ ” Gas Pipe Capable Up to 24′
  • Field Convertible Gas System
  • Dual Stainless Steel Heat Exchangers
  • 93.5% AFUE
  • SCH 40, 2″ PVC Venting up to 60′
  • Integrated control

Application: Indoor; Gas Type: NG/LP; Min. BtuH
Input: 14,000; Max. BtuH Input: 150,000; Hot Water @ 35°F Rise Capacity:
4.0 GPM; Hot Water @ 70°F Rise Capacity: 3.4 GPM; Width: 17″; Height:
28″; Depth: 12″; Wt. Lbs.: 84;

  • Super condensing efficiency
  • Dual stainless steel heat exchangers
  • SCH40, 2” PVC venting up to 60’
  • ½” Gas pipe up to 24’
  • Automatic water filling system
  • integrated controls
  • Data Field NCB-180
    Gas Input Space Heating 14,000-80,000 BTU/H
    Domestic Hot Water 14,000-150,000 BTU/H
    AFUE 95.0%
    Flow Rate (DHW) 77°F (43°C) Temp Rise 3.4 GPM (12.9 L/m)
    Dimensions 17″(W) x 28″(H) x
    12″(D)
    Weight 74 lbs (34kg)
    Installation Type Indoor Wall-Hung
    Venting Type Forced Draft Direct
    Vent
    Ignition Electronic Ignition
    Water Pressure (Hydronic/DHW) 12-30 PSI / 15-150
    PSI
    Natural Gas Supply Pressure (from source) 3.5″-10.5″ WC
    Propane Gas Supply Pressure (from source) 8.0″-13.5″ WC
    Natural Gas Manifold Pressure (min to max) -0.07″ WC to -0.66”
    WC
    Propane Gas Manifold Pressure (min to max) -0.06″ WC to -0.62″
    WC
    Minimum Flow Rate (DHW) 0.5 GPM (1.9 L/m)
    Connection Sizes Heating Supply/Return 1″ NPT
    DHW Inlet/Outlet 3/4″ NPT
    Gas Inlet 3/4″ NPT
    Auto Feeder 1/2″ NPT
    Condensate Outlet 1/2″ NPT
    Power Supply Main Supply 120V AC, 60Hz
    Maximum Power Consumption 200W (up to 2
    amperes)
    Materials Casing Cold Rolled Carbon
    Steel
    Heat Exchangers Primary/Secondary
    Heat Exchanger:
    Stainless Steel
    DHW Heat Exchanger:
    Stainless Steel
    Venting Exhaust 2” or 3″ PVC, CPVC,
    Polypropylene
    2” or 3″ Special Gas
    Vent Type BH (Class
    II, A/B/C)
    Intake 2” or 3″ PVC, CPVC,
    Polypropylene
    2” or 3″ Special Gas
    Vent Type BH (Class
    II, A/B/C)
    Vent Clearances 0″ to Combustibles
    Safety Devices Flame Rod, APS, Gas
    Valve Operation
    Detector, Ignition
    Operation Detector,
    Water
    Temperature High
    Limit Switch,
    Exhaust Temperature
    High Limit Sensor

Additional information