Data Field |
NCB-180
|
Gas Input |
Space Heating |
14,000-80,000 BTU/H
|
Domestic Hot Water |
14,000-150,000 BTU/H
|
AFUE |
95.0%
|
Flow Rate (DHW) |
77°F (43°C) Temp Rise |
3.4 GPM (12.9 L/m)
|
Dimensions |
17"(W) x 28"(H) x
12"(D)
|
Weight |
74 lbs (34kg)
|
Installation Type |
Indoor Wall-Hung
|
Venting Type |
Forced Draft Direct
Vent
|
Ignition |
Electronic Ignition
|
Water Pressure (Hydronic/DHW) |
12-30 PSI / 15-150
PSI
|
Natural Gas Supply Pressure (from source) |
3.5"-10.5" WC
|
Propane Gas Supply Pressure (from source) |
8.0"-13.5" WC
|
Natural Gas Manifold Pressure (min to max) |
-0.07" WC to -0.66”
WC
|
Propane Gas Manifold Pressure (min to max) |
-0.06" WC to -0.62"
WC
|
Minimum Flow Rate (DHW) |
0.5 GPM (1.9 L/m)
|
Connection Sizes |
Heating Supply/Return |
1" NPT
|
DHW Inlet/Outlet |
3/4" NPT
|
Gas Inlet |
3/4" NPT
|
Auto Feeder |
1/2" NPT
|
Condensate Outlet |
1/2" NPT
|
Power Supply |
Main Supply |
120V AC, 60Hz
|
Maximum Power Consumption |
200W (up to 2
amperes)
|
Materials |
Casing |
Cold Rolled Carbon
Steel
|
Heat Exchangers |
Primary/Secondary
Heat Exchanger:
Stainless Steel
DHW Heat Exchanger:
Stainless Steel
|
Venting |
Exhaust |
2” or 3" PVC, CPVC,
Polypropylene
2” or 3" Special Gas
Vent Type BH (Class
II, A/B/C)
|
Intake |
2” or 3" PVC, CPVC,
Polypropylene
2” or 3" Special Gas
Vent Type BH (Class
II, A/B/C)
|
Vent Clearances |
0" to Combustibles
|
Safety Devices |
Flame Rod, APS, Gas
Valve Operation
Detector, Ignition
Operation Detector,
Water
Temperature High
Limit Switch,
Exhaust Temperature
High Limit Sensor
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|